High Voltage Disconnector Switches
High-quality HV disconnector switches for reliable power system isolation and maintenance safety – engineered to exceed international standards.
- ISO Certified
- IEC Standards
- Factory Tested
- Global Shipping
Why Choose Our Disconnector Switches?
With over 10 years of manufacturing excellence, we’ve established ourselves as a trusted partner for power utilities and industrial clients worldwide.
Professional Expertise
Our team includes engineers with decades of experience in electrical power systems and switchgear design.
- 20+ years industry experience
- Engineering-led design approach
- In-house testing facilities
- Continuous innovation program
Certified Quality
Our products meet rigorous international standards and undergo independent testing for reliability and safety.
- ISO 9001 certified manufacturing
- IEC 62271-102 compliance
- ANSI/IEEE standard adherence
- Third-party type testing
Professional Expertise
Our team includes engineers with decades of experience in electrical power systems and switchgear design.
- 20+ years industry experience
- Engineering-led design approach
- In-house testing facilities
- Continuous innovation program
Let's Talk About Your hv disconnector switch Needs
To ensure quick matching of the most suitable hv disconnector switch for you, please provide the voltage level, load current, and installation environment (such as indoor/outdoor) of the existing system, and we will immediately recommend an optimization solution for you!
Product Categories
Our comprehensive range of disconnector switches is designed to meet diverse requirements across electricity transmission and distribution systems. Browse our catalog to find the perfect solution for your specific application.
By Voltage Level
12kV Disconnector Switch
24kV Disconnector Switch
33kV Disconnector Switch
40.5kV Disconnector Switch
High Voltage Disconnector Switches
66kV
Transmission Class
110kV
Transmission Class
220kV & Above
Ultra High Voltage
Our high voltage range includes disconnector switches for critical transmission infrastructure and major substations, with voltage ratings of 66kV, 110kV, 220kV and above.
Disconnector with Earth Switch
Integrated units combining isolation and earthing capabilities in a single device. The earthing switch grounds the disconnected circuit, discharging residual voltage and providing additional safety.
Key Features:
- Mechanical interlocking
- Position indicators
- Robust earth connection
- Multiple operation options
Motor Operated Disconnector
Motorized operation system for remote control capabilities, allowing operation from control centers or SCADA systems without requiring personnel at the installation site.
Key Features:
- Remote operation
- Status feedback
- Manual override
- Programmable controllers
By Special Features
Complete Product List
| Model | Voltage Class | Current Rating | Installation | Operation | Earth Switch | |
|---|---|---|---|---|---|---|
| DJ-12-630-M | 12kV | 630A | Indoor | Manual | Optional | |
| DJ-12-1250-E | 12kV | 1250A | Indoor | Motorized | Yes | |
| DJ-24-800-M | 24kV | 800A | Indoor | Manual | No | |
| DJ-24-1600-E | 24kV | 1600A | Outdoor | Motorized | Yes | |
| DJ-33-1250-M | 33kV | 1250A | Indoor | Manual | Optional | |
| DJ-40-2000-E | 40.5kV | 2000A | Outdoor | Motorized | Yes | |
Understanding Disconnector Switches
Main Components of a VCB
By Operation Method:
Manual operation:
Operated by hand using levers or handles, suitable for installations with infrequent switching requirements.
Motor-driven operation:
Electric motors provide remote operation capabilities, ideal for automated substations and SCADA systems.
Pneumatic operation:
Uses compressed air for faster operation, commonly found in legacy systems and specialized applications.
By Installation Location:
Indoor disconnectors:
Designed for protected environments with standard insulation levels and compact dimensions.
Outdoor disconnectors:
Weather-resistant design with enhanced insulation, UV protection, and pollution resistance for exposed installations.
By Operation Method:
Single-phase disconnectors:
Used for individual phase isolation, offering flexibility in operation but requiring more space and maintenance.
Three-phase disconnectors:
Operate all three phases simultaneously with a single mechanism, saving space and simplifying operation.
By Design Structure:
Center-break type:
Opens at the center with two rotating arms, providing good electrical clearance in compact space.
Double-break type:
Features two breaking points per phase for enhanced reliability and voltage withstand capability.
Pantograph type:
Vertical movement with scissors-like mechanism, ideal for high-voltage applications with space constraints.
Disconnectors in Substations
Disconnectors serve multiple critical functions in substations, forming an essential part of the isolation and switching scheme. Their strategic placement throughout the substation allows for flexible operation and maintenance without compromising system reliability or personnel safety.
Bus disconnectors:
Isolate sections of busbars, allowing maintenance on specific portions while keeping the rest of the substation operational. This arrangement is crucial for system flexibility.
Line disconnectors:
Isolate transmission/distribution lines from the substation, enabling maintenance work on lines without de-energizing the entire substation.
Bypass disconnectors:
Allow equipment (typically circuit breakers) to be bypassed for maintenance without interrupting service, ensuring continuous power supply during maintenance.
Equipment disconnectors:
Isolate specific equipment like transformers, capacitor banks, or reactors for safe maintenance operations without affecting other parts of the system.
Safety Interlocking Systems
Modern substations implement sophisticated mechanical and electrical interlocking systems to prevent dangerous operating sequences. These interlocks ensure that:
- Disconnectors cannot be operated under load
- Earth switches cannot be closed when the circuit is energized
- Circuit breakers cannot be closed when maintenance is in progress
- Operating sequences follow mandatory safety protocols
Disconnector Switch Operating Sequence Examples
Equipment Isolation Procedure
- Open associated circuit breaker to interrupt load current
- Verify circuit breaker open status via indicators or SCADA
- Open line-side disconnector
- Open bus-side disconnector
- Close associated earth switch if available
- Verify isolation via visible gap inspection
- Apply lockout-tagout devices as per safety protocols
- Test for absence of voltage before work begins
Equipment Return to Service Procedure
- Complete all maintenance work and remove tools/equipment
- Remove lockout-tagout devices
- Open earth switch if closed
- Close bus-side disconnector
- Close line-side disconnector
- Verify proper disconnector closure
- Close associated circuit breaker to restore load current
- Verify normal operation indicators
Disconnector Switch Application Scenarios
Disconnector Switch In Power Transmission
High voltage disconnectors are critical components in transmission substations, providing isolation for maintenance of transformers, circuit breakers, and transmission lines.
- EHV and UHV transmission substations
- Switching stations at grid interconnections
- Regional load dispatch centers
Disconnector Switch In Distribution Networks
Medium voltage disconnectors are essential in distribution substations and underground cable networks, enabling sectional isolation and maintenance.
- Urban distribution substations
- Ring main units and switching points
- Secondary substations feeding commercial areas
Disconnector Switch In Industrial Power Systems
Industries with high power requirements use disconnectors in their private substations and distribution systems for reliable power management.
- Manufacturing facilities with high electrical loads
- Mining operations and processing plants
- Steel mills and heavy industrial complexes
Disconnector Switch In Renewable Energy
Solar farms, wind parks and other renewable energy installations require disconnectors for safe isolation during maintenance and grid connection management.
- Solar power collector substations
- Wind farm switching stations
- Grid connection points for renewable sources
Disconnector Switch In Railway Electrification
Electrified railway systems deploy specialized disconnectors in traction substations and sectioning posts for maintenance and emergency isolation.
- Traction power substations
- Sectioning and paralleling posts
- Switching stations along electrified routes
Disconnector Switch In Data Centers
Modern data centers with critical power needs utilize disconnectors in their power distribution systems to ensure reliable maintenance without service interruptions.
- Hyperscale data center power systems
- Colocation facility electrical infrastructure
- Backup power integration points
Technical Resources
HV Disconnector Wiring Diagrams
We provide comprehensive wiring diagrams for our disconnector switches to assist with installation and maintenance. These diagrams show the control circuit connections for various operation modes.
HV Disconnector Structure Diagrams
Our disconnector switches consist of several key components working together to provide reliable isolation. Understanding these components is essential for proper maintenance and troubleshooting.
Frequently Asked Questions
A: A disconnector switch, often simply called a disconnector or isolator, is a mechanical switching device. Its primary purpose is to provide a visible and safe isolating gap in an electrical circuit, ensuring that a section of the circuit is de-energized and isolated from the power supply. This is crucial for maintenance, repair, or inspection work on equipment downstream.
A: In many contexts, especially concerning safety isolation, “isolator switch” and “disconnector switch” are used interchangeably to refer to a device that provides a visible isolation gap. However, it’s important to note that a “switch disconnector” (or load break switch) might have the additional capability of making or breaking normal load currents, whereas a pure disconnector/isolator is typically operated only under no-load conditions.
A:
- A Disconnector Switch (or Isolator) is primarily designed to provide a visible safety isolation point. It is generally operated only when the circuit is already de-energized (no significant current flowing). It may have a limited capacity to break small charging currents of busbars or short cable lengths.
- A Switch Disconnector (or Load Break Switch) can both provide isolation AND is capable of making and breaking normal operating currents (load currents). However, it is typically not designed to break fault currents (short circuits).
A: Yes, we offer a range of disconnector switches designed for various medium voltage levels, including 12kV, 24kV, 33kV, and 40.5kV. Please specify your required voltage rating when inquiring.
A: High Voltage (HV) disconnector switches are designed for use in high voltage power systems, typically from 66kV and above, up to ultra-high voltages like 500kV, 765kV, or even higher. We manufacture and supply a comprehensive range of HV disconnector switches. Please let us know your specific HV application requirements.
A: HV disconnector switches come in various types based on their construction and operating mechanism, including: * Centre-break disconnectors * Double-break disconnectors * Pantograph disconnectors * Vertical break disconnectors * Knee-type disconnectors They can also be classified by their operating mechanism (manual, motor-operated) and whether they include an earthing switch.
A: A disconnector with an integrated earth switch (or earthing switch) combines the functions of isolation and earthing into a single unit. After the main disconnector blades open to isolate the circuit, the earth switch can be closed to connect the isolated section to ground. This provides an additional layer of safety for personnel working on the de-energized equipment by ensuring it’s at earth potential and discharging any trapped charges.
A: In a substation, disconnector switches are vital for: * Isolating circuit breakers for maintenance. * Isolating transformers, busbars, or sections of a busbar. * Isolating incoming or outgoing lines. * Transferring load between different busbars using bypass disconnectors. They ensure that equipment can be safely worked on without the risk of energization.
A: Yes, detailed technical information, including electrical specifications, typical wiring diagrams, and general arrangement/structural diagrams, is available in our product datasheets and technical manuals. For specific project requirements or custom diagrams, please contact our technical support team.
A: To get a price for a disconnector switch, please contact our sales team or submit a request for a quotation (RFQ) with your specific requirements. Key factors influencing the price include: * Voltage rating (e.g., 12kV, 33kV, 220kV) * Current rating * Type of disconnector (e.g., centre break, pantograph) * Whether an earth switch is required * Operating mechanism (manual, motorized) * Any special features or compliance standards * Quantity required
A: Yes, we are a specialized manufacturer of a wide range of disconnector switches, from medium voltage to extra-high voltage applications. We pride ourselves on quality, reliability, and adherence to international standards.
A: Key considerations include: * System Voltage: The rated voltage of the disconnector must match or exceed your system voltage. * Rated Current: The continuous current carrying capacity. * Short-time Withstand Current: Ability to withstand fault currents for a specified duration. * Insulation Level (BIL/SIL): Must be adequate for a_z_system’s transient overvoltages. * Operating Environment: Indoor/outdoor, altitude, temperature, pollution level. * Type of Operating Mechanism: Manual or motorized. * Need for an Earth Switch: For safety during maintenance. * Space Constraints: Physical dimensions and mounting requirements. * Applicable Standards: IEC, ANSI, etc.
Pricing and Procurement
Factors Affecting Disconnector Switch Prices
The cost of disconnector switches can vary significantly based on several factors. Understanding these variables will help you budget appropriately for your project requirements.
Voltage and Current Ratings
Higher voltage and current ratings require more robust materials and construction techniques, significantly increasing costs. Ultra-high voltage disconnectors (220kV and above) have specialized design requirements that further impact pricing.
Operating Mechanism Type
Motorized options with remote control capabilities cost considerably more than basic manual models. Advanced options with intelligent controllers, position sensors, and SCADA integration add to the overall price point.
Inclusion of Earth Switch
Integrated earth switches require additional mechanical components and safety interlocks, increasing the manufacturing complexity and cost. Models with earth switches typically cost 20-30% more than standard disconnectors.
Material Quality
Premium materials such as silver-plated contacts, high-grade insulators, and corrosion-resistant components improve performance in harsh environments but add to the cost. The quality of materials directly impacts reliability and lifespan.
Order Quantity
Bulk orders typically qualify for volume discounts, potentially reducing per-unit costs by 10-15%. For large substation projects, requesting a comprehensive package quote can often result in better overall pricing.
Request a Quote
Fill out the form below with your project details, and our sales team will provide a customized quotation tailored to your specific requirements within 24 hours.
Decoding Transformer Nameplates: Complete Guide to Ratings (kVA, Voltage, Impedance)
Decoding Transformer Nameplates: Complete Guide to Ratings (kVA, Voltage, Impedance) Master the critical information hidden in plain sight on every power transformer nameplate 💡 Engineering Insight from the Field As a senior electrical engineer, I...
Read MorePower Transformer vs. Distribution Transformer: 7 Key Differences
Power Transformer vs. Distribution Transformer: Key Differences and Application Analysis Author: ElecBase Engineering Team | Last Updated: January 2025 Reading Time: 8 minutes | Technical Level: Intermediate to Advanced Table of Contents Introduction: Understanding the...
Read MoreThe Ultimate Guide to Step-Up Power Transformers
The Ultimate Guide to Step-Up Power Transformers The Ultimate Guide to Step-Up Power Transformers Step-up transformers are foundational pillars of modern electrical grids, yet their monumental importance is often overlooked. As the powerful gateways between...
Read MoreStep-Down Transformer 101: The Ultimate Guide to How They Power Your World
Step-Down Transformer 101: The Ultimate Guide to How They Power Your World From the power grid to your wall socket, discover the unsung hero that makes our modern lives possible. This guide covers everything an...
Read MoreWhat Are the Types of SF6 Circuit Breakers?
What Are the Types of SF6 Circuit Breakers? Choosing the right SF6 circuit breaker can be confusing. Making the wrong choice can lead to operational issues or safety risks. Understanding the core classifications simplifies the...
Read More