- Power Rating: 50 kVA to 5000 kVA
- Standards: IEC 60076, ANSI/IEEE C57.12.34
- Configurations: Loop Feed & Radial Feed
- Dielectric Fluid: Mineral Oil or FR3™ Natural Ester Fluid
Trusted by Industry Leaders & Certified for Global Standards:
Find the Right Transformer for Your Application
We offer a wide range of standard models and full customization capabilities to meet your project's precise requirements.
| Model | Capacity (kVA) | HV Voltage (kV) | LV Voltage (V) | Feed Type | Standards | Datasheet |
|---|---|---|---|---|---|---|
| EBP-50 | 50 | 11, 13.8, 22 | 240/120, 480/277 | Loop/Radial | IEC/ANSI | Download |
| EBP-150 | 150 | 11, 13.8, 22 | 240/120, 480/277 | Loop/Radial | IEC/ANSI | Download |
| EBP-500 | 500 | 11, 13.8, 22, 33 | 480/277, 400/230 | Loop/Radial | IEC/ANSI | Download |
| EBP-1000 | 1000 | 13.8, 22, 33, 35 | 480/277, 400/230 | Loop/Radial | IEC/ANSI | Download |
| EBP-2500 | 2500 | 13.8, 22, 33, 35 | 480, 600 | Loop/Radial | IEC/ANSI | Download |
| Custom | Up to 5000 | Your Spec | Your Spec | Your Spec | On Request | Request Custom |
Need a different configuration? Our engineers are ready to assist. Contact Our Team.
Engineered for Performance, Safety, and Longevity
Every component of an ElecBase transformer is designed with purpose, delivering tangible benefits to our clients.
Enhanced Safety by Design
Our transformers feature a tamper-proof, dead-front design, segregating HV and LV compartments. This minimizes risk of accidental contact, ensuring maximum safety for personnel and the public.
Operational Reliability
With optional loop feed configurations, our transformers allow for greater grid flexibility and significantly reduced downtime during faults, improving key reliability metrics like SAIDI and SAIFI.
Built to Last
Constructed with heavy-gauge, corrosion-resistant steel and a multi-stage powder coating process, our transformers withstand the harshest environments, ensuring a long, maintenance-light service life.
Low Loss & High Efficiency
Utilizing high-grade amorphous alloy or silicon steel cores, our transformers are optimized for low no-load and full-load losses, resulting in lower operational costs and a reduced carbon footprint.
Global Compliance
Designed and tested to meet or exceed major international standards, including IEC and ANSI/IEEE. We provide full type and routine test reports with every unit, ensuring hassle-free commissioning worldwide.
Custom Engineering
Beyond standard models, our engineering team excels at creating bespoke solutions. We can modify dimensions, accessories, and protection schemes to meet unique site conditions and specifications.
Anatomy of an ElecBase Pad-Mounted Transformer
High-Voltage (HV) & Low-Voltage (LV) Compartments
Safety and accessibility are paramount. Our transformers are divided into two isolated, front-accessible compartments secured with tamper-resistant locks.
- High-Voltage (HV): Features a dead-front design using load-break elbow connectors. It houses bay-o-net fuses for overload protection and isolation links for high-fault events, ensuring safe operation and maintenance.
- Low-Voltage (LV): Provides stepped-down voltage via spade or threaded-stud terminals. Optional secondary breakers can be included for additional protection, along with a clearly accessible system ground lug.
Radial Feed vs. Loop Feed
The primary connection configuration is critical for system reliability. We offer both options to suit different network designs.
- Radial Feed: A simple, cost-effective solution where a single primary cable feeds one or more transformers. Ideal for areas where outages on the main line are less critical.
- Loop Feed: The cornerstone of modern, reliable underground distribution. The primary cable forms a loop, allowing a faulted section to be isolated while restoring power to other customers from the opposite direction. This drastically improves system availability.
The Heart of the Transformer
Efficiency and longevity start at the core. The main tank is hermetically sealed and filled with dielectric fluid for insulation and cooling.
- Core & Coils: We use precisely wound copper or aluminum coils and low-loss steel cores to maximize efficiency and minimize heat generation.
- Dielectric Fluid: Standard units use high-grade mineral oil. For enhanced fire safety and environmental friendliness, we offer FR3™ natural ester fluid, a less-flammable and biodegradable alternative.
Powering Diverse Sectors
Our pad-mounted transformers are the trusted choice for a wide variety of critical applications across the globe.

Utility & Residential Distribution

Commercial Centers & Shopping Malls

Industrial Parks & Manufacturing

Renewable Energy Projects

Critical Infrastructure (Hospitals, Data Centers)

Educational & Institutional Campuses
Frequently Asked Questions for Buyers & Engineers
What international standards do your transformers meet?
Our pad-mounted transformers are designed, manufactured, and tested to comply with major international standards, including IEC 60076 and ANSI/IEEE C57.12.34. We provide certified factory acceptance test (FAT) reports with every unit to guarantee compliance and performance.
Can you customize ratings and features to our project specifications?
Absolutely. Customization is a core strength of ElecBase. We can tailor voltage ratings, kVA capacity, impedance, tap arrangements, and accessories (such as pressure relief devices, gauges, and specific fusing options) to your exact project requirements. Simply provide your technical specification sheet with your inquiry.
What is the typical manufacturing lead time?
Lead times vary based on complexity and current production schedules. Standard models typically have a lead time of 8-12 weeks. Fully custom-engineered transformers may require 12-16 weeks. Please contact us with your project timeline for a precise estimate.
What are your shipping and logistics capabilities?
We ship globally. Our dedicated logistics team handles everything from secure, robust crating designed for heavy equipment to international freight management (sea or air) and customs documentation, ensuring your transformer arrives safely, on time, and ready for installation.
What warranty and after-sales support do you offer?
We offer a standard 24-month warranty from the date of shipment, covering defects in materials and workmanship. Extended warranties and comprehensive after-sales support packages, including remote technical assistance and spare parts supply, are also available upon request.
Let's Build Your Next Power Solution
Tell us about your project requirements. Our engineering team will review your specifications and provide a detailed, no-obligation quote within 24-48 business hours.
SUBMIT MY INQUIRY NOWDecoding Transformer Nameplates: Complete Guide to Ratings (kVA, Voltage, Impedance)
Decoding Transformer Nameplates: Complete Guide to Ratings (kVA, Voltage, Impedance) Master the critical information hidden in plain sight on every power transformer nameplate 💡 Engineering Insight from the Field As a senior electrical engineer, I...
Read MorePower Transformer vs. Distribution Transformer: 7 Key Differences
Power Transformer vs. Distribution Transformer: Key Differences and Application Analysis Author: ElecBase Engineering Team | Last Updated: January 2025 Reading Time: 8 minutes | Technical Level: Intermediate to Advanced Table of Contents Introduction: Understanding the...
Read MoreThe Ultimate Guide to Step-Up Power Transformers
The Ultimate Guide to Step-Up Power Transformers The Ultimate Guide to Step-Up Power Transformers Step-up transformers are foundational pillars of modern electrical grids, yet their monumental importance is often overlooked. As the powerful gateways between...
Read MoreStep-Down Transformer 101: The Ultimate Guide to How They Power Your World
Step-Down Transformer 101: The Ultimate Guide to How They Power Your World From the power grid to your wall socket, discover the unsung hero that makes our modern lives possible. This guide covers everything an...
Read MoreWhat Are the Types of SF6 Circuit Breakers?
What Are the Types of SF6 Circuit Breakers? Choosing the right SF6 circuit breaker can be confusing. Making the wrong choice can lead to operational issues or safety risks. Understanding the core classifications simplifies the...
Read More