Leading Vacuum Circuit Breaker Manufacturer

Advanced & Reliable Vacuum Circuit Breakers

Zhejiang Dianji Power delivers premium indoor & outdoor VCB solutions with exceptional performance and durability for voltages up to 35kV.

Home / Vacuum Circuit Breakers
OUR PRODUCT LINEUP

Comprehensive Vacuum Circuit Breaker Products

Explore our extensive range of high-performance vacuum circuit breakers designed for various voltage levels and applications

One-stop solution for vacuum circuit breakers

INDOOR VACCUM CIRCUITS BREAKERS 11KV- 33KV

ZN63A(VS1)-12 series indoor high voltage vacuum circuit breaker_02
ZN63A(VS1)-12 series indoor high voltage vacuum circuit breaker_02

Main technical parameters of ZN63A (VS1)-12 series indoor high voltage vacuum circuit breaker

The VS1-12 indoor high-voltage vacuum circuit breaker is an indoor switchgear for three-phase AC 50Hz rated voltage 12kV power system, used as a protection and control unit for power grid equipment and industrial and mining power equipment. It is suitable for places that require frequent operation at rated working current or multiple short-circuit current interruption.

The circuit breaker adopts an integrated design of operating mechanism and circuit breaker body, which can be used as a fixed installation unit or equipped with a special propulsion mechanism to form a trolley unit.

VBP.12 SeriesIndoor Medium Voltage Sealed Vacuum circuit Breaker
VBP.12 SeriesIndoor Medium Voltage Sealed Vacuum circuit Breaker

Main technical parameters of VBP 12 Series Indoor Medium Voltage Sealed Vacuum circuit Breaker

VBP indoor medium voltage sealed vacuum circuit breaker is a new generation of vacuum circuit breaker developed by our company. VBP vacuum circuit breaker is suitable for indoor switch with air insulation, and is used for control and protection in power grid with AC 50Hz and rated voltage of 12Kv and below.

VBP vacuum circuit breaker has extremely excellent performance in occasions of frequent operation and short-circuit current breaking, fully meets the requirements of automatic reclosing and has high reliability operation and service life.

ZN63(VS1)-12 series side-mounted indoor high voltage vacuum circuit breaker
ZN63(VS1)-12 series side-mounted indoor high voltage vacuum circuit breaker

Main technical parameters of ZN63(VS1)-12 series side-mounted indoor high voltage vacuum circuit breaker

ZN63A (VS1) -12 side-mounted vacuum circuit breaker is an indoor high-voltage switchgear, suitable for three-phase power systems with a rated voltage of 12 kV and a frequency of 50 Hz. It is used as a protection and control device. Due to the special advantages of vacuum circuit breakers, it is particularly suitable for places that require frequent operations under rated current or multiple short-circuit current interruption.

ZN63A (VS1) -12 side-mounted vacuum circuit breaker adopts fixed installation and is mainly used in fixed switch cabinets. The breaker can be used alone or in ring network power supply, box-type transformer or various non-standard power supply systems.

ZN63 (VS1) - 24kV Series 24kV Indoor High Voltage Vacuum Circuit Breaker

Main technical parameters of ZN63 (VS1) - 24kV Series Indoor High Voltage Vacuum Circuit Breaker

VS1-24 type indoor high voltage vacuum circuit breaker, a three-phase AC 50 Hz rated voltage 24kV power system indoor switchgear, serving as the protection and control unit for power grid equip￾ment and industrial and mining enterprise power equipment. Applicable to environments requiring fre￾quent operation under rated working current or multiple interruptions of short-circuit current.

This circuit breaker features an integrated design of the operating mechanism and the
circuit breaker body, allowing it to function as a fixed installation unit or to be equipped with a
dedicated trolley mechanism to form a withdrawable unit.

VZF-12R Series Withdrawable Vacuum Load Switch-Fuse Combination Apparatus
VZF-12R Series Withdrawable Vacuum Load Switch-Fuse Combination Apparatus

Main technical parameters of VZF-12R Series Withdrawable Vacuum Load Switch-Fuse Combination Apparatus

The VZF-12R center-sealed vacuum load switch-fuse combination apparatus  (hereinafter referred to as the vacuum load switch) represents the latest generation of vacuum switching equipment developed based on a specialized design concept aligned with market demands. It is widely used in indoor metal-clad air-insulated switchgear.

Complies with standards GB3804-2004, GB16926–1997, and others. The VZF-12R center-mounted sealed vacuum load switch-fus  combination device ensures safe and reliable operation within the technical parameter range of the vacuum switch under normal operating conditions and in power systems of the corresponding voltage level.

ZN28 (A)-12 Series Indoor high voltage vacuum circuit breaker
ZN28 (A)-12 Series Indoor high voltage vacuum circuit breaker

Main technical parameters of ZN28 (A)-12 Series Indoor high voltage vacuum circuit breaker

The ZN28-12 series vacuum circuit breaker is a high-voltage indoor switchgear with a rated voltage of 12 kV and three-phase AC 50 Hz. This product complies with the GB1984-89 standard.

The overall structure consists of two installation types: integrated installation of the switch body and oper￾ating mechanism, and separate installation of the switch body and operating mechanism. The inte￾grated structure corresponds to the ZN28-12 basic model; The separated structure corresponds to the ZN28A-12 model, suitable for various fixed switchgear cabinets, such as GG1A(Z), XGN2A10(Z), etc.

This product can be equipped with CD17 and CD10 type DC electromagnetic operating mecha￾nisms, as well as CT17 and CT19 type spring energy storage operating mechanisms.

ZN23-40.5 Series Indoor high voltage vacuum circuit breaker
ZN23-40.5 Series Indoor high voltage vacuum circuit breaker

Main technical parameters of ZN23-40.5 Series Indoor high voltage vacuum circuit breaker

The ZN23-40.5 model vacuum circuit breaker is an indoor high voltage electrical device with a rated voltage of 40.5 kV and three-phase AC 50 Hz. It is suitable for industrial and mining enterprises, substations, and other power transmission and distribution systems, serving as a con￾trol and protection switch.

It is especially applicable to industries such as metallurgy and electric arc steelmaking that require frequent operation, functioning as control and protection equipment.


Model and Definition Rated short-circuit breaking current
· Rated Current Withdrawable type Rated voltage Design serial number This product complies with the GB1984-89 standard ‘AC High Voltage Circuit Breakers.

ZN85-40.5 Series Indoor high voltage vacuum circuit breaker
ZN85-40.5 Series Indoor high voltage vacuum circuit breaker

Main technical parameters of ZN85-40.5 Series Indoor high voltage vacuum circuit breaker

The ZN85-40.5 (3AV3) Indoor Vacuum Circuit Breaker is jointly de￾signed and manufactured by the company and the Xi’an High Voltage Elec￾trical Apparatus Research Institute. This product is suitable for indoor high voltage equipment with a rated voltage of 40.5 kV and three-phase AC 50 Hz. It is intended for use by industrial and mining enterprises, power plants, and substations to make and break load current, overload current, and short circuit current, and is suitable for frequent operation conditions.

OUTDOOR VACCUM CIRCUITS BREAKERS11KV- 35KV

ZW32-12 series outdoor high voltage vacuum circuit breaker
ZW32-12 series outdoor high voltage vacuum circuit breaker

Main technical parameters of ZW32-12 series outdoor high voltage vacuum circuit breaker

The ZW32-12 series outdoor AC high-voltage vacuum circuit breaker (hereinafter referred to as the circuit breaker) is an outdoor distribution device rated at 12kV and three-phase AC 50Hz. It is primarily used for breaking and closing load current, overload current, and short-circuit current in electrical systems. It is suitable for protection and control in substations and industrial and mining enterprise distribution systems, as well as in rural power grids with frequent switching operations. Can also serve as a sectionalizing switch in the power grid; with the addition of a controller, distribution network automation can be achieved.

ZW32-12M Series Outdoor High Voltage Permanent Magnet Vacuum Circuit Breaker

Main technical parameters of LW36-126 72KV 126KV 145KV 220kv Sf6 Circuit Breaker

The ZW32M-12 model outdoor high voltage permanent magnet vacuum circuit breaker (hereinafter referred to as the circuit breaker) is an outdoor distribution device with a rated voltage of 12 kV and three-phase AC 50 Hz. It is primarily used for interrupting and closing load current, overload current, and short-circuit current in power systems. Suitable for protection and  ontrol in substations and power distribution systems of industrial and mining enterprises, as well as locations with frequent operations in rural power grids.

Model and Definition· Rated Short-Circuit Breaking Current This circuit breaker features a compact size, light weight, anti-condensation properties, and maintenance-free operation, enabling it to withstand harsh climatic conditions and polluted environments. Rated current· Rated voltage· Permanent magnet operating mechanism.

This product utilizes a permanent magnet operating mechanism for operation; Because the permanent magnet operating mechanism provides holding force via permanent magnets, it keeps the switch in the open or closed position. The mechanism contains fewer mechanical components and a shorter me￾chanical transmission chain, thereby greatly enhancing the reliability and mechanical lifespan of the switch.

ZW32L-12 Series Outdoor High Voltage Zero Sequence Intelligent Vacuum Circuit Breaker

Main technical parameters of ZW32L-12 Series Outdoor High Voltage Zero Sequence Intelligent Vacuum Circuit Breaker

The ZW32L-12 series outdoor high voltage zero-sequence intelligent vacuum circuit breaker (hereinafter referred to as the zero-sequence intelligent circuit breaker) is an outdoor distribution device with a rated voltage of 12 kV and three-phase AC 50 Hz.

It is primarily used to interrupt and close load current, overload current, and short-circuit current in electronic systems. Suitable for protection and control in substations and power distribution systems of industrial and mining enterprises, as well as locations with frequent operations in rural power grids. It can also function as a ctionalizing switch in the power grid; with the addition of a controller, it can achieve distribution network automation.

ZW32-12F series Outdoor High Voltage Intelligent Vacuum Circuit Breaker

Main technical parameters of ZW32-12F series Outdoor High Voltage Intelligent Vacuum Circuit Breaker

The ZW32-12F type outdoor high voltage intelligent vacuum circuit breaker (sectionalizing switch, commonly referred to as “Watchdog”) is an outdoor distribution device rated at 12 kV, three-phase AC 50 Hz. It is primarily used to open and close load current, overload current, and short circuit current in power systems. It is suitable for protection and control in substations and distribution systems of in￾dustrial and mining enterprises, as well as locations with frequent operations in rural power grids.

This circuit breaker features a compact size, light weight, anti-condensation, and maintenance -free design, enabling it to operate under harsh climatic conditions and polluted environments.

ZW32-24 (F) Series Outdoor High Voltage (Intelligent) Vacuum Circuit Breaker

ZW32-24 (F) Series Outdoor High Voltage (Intelligent) Vacuum Circuit Breaker

The ZW32-24 kV Outdoor AC High Voltage Vacuum Circuit Breaker (hereinafter referred to as the Circuit Breaker) is outdoor distribution equipment with a rated voltage of 24 kV, 50 Hz three-phase AC. It is primarily used for interrupting and closing load current, overload cur￾rent, and short-circuit current in power distribution networks. It is suitable for protection and control in substations and distribution systems of industrial and mining enterprises, and is especially appropriate for rural power grids and locations requiring frequent operation.

ZW20-12 Series Outdoor High Voltage Vacuum Circuit Breaker
ZW20-12 Series Outdoor High Voltage Vacuum Circuit Breaker

Main technical parameters of ZW20-12 Series Outdoor High Voltage Vacuum Circuit Breaker

The ZW20B-12 outdoor pole-mounted high voltage vacuum circuit breaker is an outdoor high voltage switching device with a rated voltage of 12 kV and three-phase AC 50 Hz. Primarily used for interrupting and closing load current, overload current, and short-circuit current in power systems.

Suitable for protection and control in substations, industrial and mining enterprises, and urban and rural distribution networks; particularly appropriate for locations with frequent operations and automated urban distribution networks. This product, in conjunction with a controller, satisfies the quirements of distribution automation systems and can reliably and effectively perform the traditional reclosing unction.

It features a mature box-type sealed structure, internally filled with SF6 gas, providing excellent sealing performance to prevent external environmental influences, making it a maintenance -free product. The spring operating mechanism employs a direct-acting chain main transmission and a multi-stage trip system, providing high operational reliability and making it an ideal choice for pole-mounted circuit breakers.

JZW32-12 Series Outdoor Pole-mounted Intelligent Prepaid Vacuum Circuit Breaker

Main technical parameters of JZW32-12 Series Outdoor Pole-mounted Intelligent Prepaid Vacuum Circuit Breaker

The JZW32-12 series outdoor pole-mounted intelligent prepaid vacuum circuit breaker is an outdoor distribution device rated at 12kV, three-phase AC 50 Hz. Primarily used for interrupting and closing load current, overload cur￾rent, and short-circuit current in the system. Suitable for protection and control in substations and power distribution systems of industrial and mining enterprises, as well as locations with frequent operations in rural power grids.

1. Intelligent control functions: This circuit breaker features local switch status control, three-stage overcurrent protection, and triple automatic reclosing. Additionally, it is equipped with an RS-485 com￾munication interface capable of implementing telemetry, remote adjustment, remote control, and remote communication functions, making it suitable for automated distribution systems of various scales.

2. Permanent magnet operating mechanism: This circuit breaker employs the most advanced permanent magnet operating mechanism currently available. The mechanism components are wear-free, and its mechanical lifespan can reach 3000 opera￾tions, which is three times that of conventional spring mechanisms. Due to the permanent magnet mechanism reducing the number of mechanical parts by 70% compared to the spring mechanism, the reliability of the switch has been greatly enhanced.

3. Fully sealed structural design: The vacuum arc extinguishing chamber, operating mechanism, and operating linkage of this circuit breaker are fully sealed within the cir￾cuit breaker base, effectively preventing corrosion caused by condensation on the components. The product can achieve maintenance-free operation for up to 10 years.

4. Compact structural design: The circuit breaker employs a new type of composite solid insulating material, organically integrating the vacuum arc extinguishing chamber, main current circuit, and insulating supports into a single integrated sealed pole, completely resolving the conflict between miniaturization of the vacuum arc extinguishing chamber and meeting external insulation requirements. The entire product design is advanced and rational, featuring a compact structure, no internal condensation, and no corrosion of the mechanism.

ZW43-12 (F) Series Outdoor High Voltage (Intelligent) Vacuum Circuit Breaker
ZW43-12 (F) Series Outdoor High Voltage (Intelligent) Vacuum Circuit Breaker

Main technical parameters of ZW43-12 (F) Series Outdoor High Voltage (Intelligent) Vacuum Circuit Breaker

The ZW43-12 (F) type outdoor high voltage (intelligent) vacuum circuit breaker is an outdoor high voltage switching device rated at 12kV and three-phase AC 50 Hz. Primarily used for interrupting and closing load current, overload current, and short-circuit current in power systems. It is suitable for protection and control in substations, industrial and mining enterprises, and urban and rural distribution networks, particularly for locations with frequent operation and urban network automated distribution systems.

It complies with the following standards: GB/T1984 ‘High Voltage AC Circuit Breakers’, GB/T11022 ‘Common Technical Require￾ments for High Voltage Switchgear and Controlgear Standards’, DI402 ‘Technical Con￾ditions for Ordering AC High Voltage Circuit Breakers.

AB-3S Series Outdoor High Voltage Permanent Magnet Vacuum Circuit Breaker
AB-3S Series Outdoor High Voltage Permanent Magnet Vacuum Circuit Breaker

Main technical parameters of AB-3S Series Outdoor High Voltage Permanent Magnet Vacuum Circuit Breaker

ZW (AB-3S) Type Outdoor High Voltage Permanent Magnet Vacuum Automatic Recloser (hereinafter referred to as ‘Recloser’) is an outdoor distribution switch with a rated voltage of 12 kV, three-phase AC 50 Hz. The Recloser is a new generation outdoor pole-mounted switch developed by our company to meet the requirements of smart grids, designed for switching various types of loads and frequent operations, and capable of multiple short-circuit current interruptions.

It can serve as the outgoing line on the 24kV side of the main transformer in substations, as well as a pole-mounted witch in dis￾tribution networks. It is the primary equipment for achieving intelligent, automated, and compact substations in distribution networks.

ZW7-40.5 Series Outdoor High Voltage Vacuum Circuit Breaker
ZW7-40.5 Series Outdoor High Voltage Vacuum Circuit Breaker

Main technical parameters of ZW7-40.5 Series Outdoor High Voltage Vacuum Circuit Breaker

The ZW7-40.5 type outdoor high voltage vacuum circuit breaker is designed for AC 50Hz, 40.5kV outdoor high voltage electrical equipment. Equipped with either a spring operating mechanism or an electromagnetic operating mechanism, it supports remote electric opening and closing, as well as manual charging and manual opening and closing on site.

The design performance complies with the requirements of the national stan￾dard GB1984-2014 ‘AC High Voltage Circuit Breakers. It also meets the requirements of the IEC 56 ‘AC High Voltage Circuit Breakers’ international standard tablished by the International Electrotechnical Commission. The ZW7-40.5 series outdoor high voltage vacuum circuit breaker is primarily used for control and protection in outdoor 35kV power transmission and transformation systems.

Let's Talk About Your VCB Needs

To ensure quick matching of the most suitable vacuum circuit breaker for you, please provide the voltage level, load current, and installation environment (such as indoor/outdoor) of the existing system, and we will immediately recommend an optimization solution for you!

COMPREHENSIVE SOLUTIONS

High Voltage & Medium Vacuum Circuit Breakers

Complete medium voltage protection systems designed for reliability, efficiency, and safety in power distribution networks

Medium Voltage 11KV Vacuum Circuit Breakers

Our medium voltage VCBs offer exceptional reliability and performance for critical power distribution applications. Available in all standard voltage levels including 6kV, 10kV, 11kV, 24kV, 33kV, and 35kV, our solutions are designed to meet the most demanding requirements.

11kV VCB Specifications

  • ated voltage: 12kV
  • Rated current: 630A-2500A
  • Breaking capacity: 25kA
  • Operating cycles: 30,000+

Current Ratings

630A to 3150A for various applications

Breaking Capacity

Up to 40kA, meeting IEC standards

Medium 24KV Voltage Circuit Breaker

Key Specifications:
Rated Voltage24kV
Rated Current630A to 1250A
Breaking Capacity25kA
Mechanical Life10,000 operations
Protection RatingIP54

Specially designed for outdoor installations in 24kV networks, these VCBs feature weather-resistant enclosures, superior insulation, and reliable performance under various environmental conditions including utility substations and renewable energy projects.

ZW7-40.5 Series Outdoor High Voltage Vacuum Circuit Breaker
Key Technical Challenges:
  • Higher dielectric strength requirements
  • Contact erosion at higher current levels
  • Mechanical stress during operation
  • Voltage distribution control
Our Innovative Solutions:
  • Advanced contact materials with reduced erosion
  • Optimized vacuum chamber design
  • Enhanced operating mechanisms
  • Field optimization techniques

High Voltage 33KV Vacuum Circuit Breakers

ZN63A-40.5/T1250-31.5 Series

Key Specifications:
Rated Voltage40.5kV
Rated Current1250A to 2500A
Breaking Capacity31.5kA
Mechanical Life10,000 operations
StandardsIEC 62271-100, GB 1984

Our high-performance 33kV VCBs are designed for primary distribution networks, renewable energy projects, and industrial applications requiring higher voltage ratings.

Interested in our high voltage solutions?

Contact our technical specialists for detailed information

TECHNICAL EXPERTISE

Understanding VCBs: Principle, Structure & Types

Explore the advanced technology behind vacuum circuit breakers and how they provide superior protection for electrical systems

What is a VCB Circuit Breaker?

Our medium voltage VCBs offer exceptional reliability and performance for critical power distribution applications. Available in all standard voltage levels including 6kV, 10kV, 11kV, 24kV, 33kV, and 35kV, our solutions are designed to meet the most demanding requirements.

Key MV VCB Applications:

Fast Breaking

Rapid interruption of fault currents due to excellent dielectric recovery properties of vacuum

High Reliability

Sealed chamber design eliminates environmental contamination and ensures consistent performance

A Vacuum Circuit Breaker (VCB) is a sophisticated electrical switching device that uses vacuum as the arc quenching medium. It represents the most advanced technology for medium voltage circuit protection, combining exceptional performance with environmental benefits.

Unlike traditional circuit breakers that use oil, air, or SF6 gas, VCBs rely on the unique properties of high vacuum (approximately 10-7 to 10-8 torr) to interrupt electrical arcs. This vacuum environment provides superior insulation and arc extinction properties, enabling VCBs to safely interrupt currents ranging from a few amperes to tens of kiloamperes.

Core Features of VCBs:

  • Vacuum Interrupters: Sealed chambers containing fixed and movable contacts where the actual current interruption occurs
  • Operating Mechanism: Spring-charged, motor-driven, or magnetic actuator system that provides the energy for opening and closing operations
  • Insulation System: High-quality insulating materials that provide electrical isolation between phases and to ground
  • Control Circuitry: Electronic or electromechanical systems for trip/close operations, monitoring, and protection functions

Primary Applications:

VCBs have become the dominant technology in medium voltage applications (1kV to 35kV) across various sectors:

VCB Breaker Working Principle & Function

The working principle of a vacuum circuit breaker is based on the rapid recovery of dielectric strength in a vacuum after current interruption. This exceptional recovery rate makes vacuum an ideal medium for breaking high currents at medium voltage levels.

 

The Arc Extinction Process:

When the contacts of a VCB separate during a fault condition, an electric arc forms between them due to the ionization of metal vapors from the contact surface. Unlike air or oil circuit breakers, this arc in vacuum has distinct characteristics:

  1. Arc Initiation: When contacts begin to separate, a metallic vapor arc forms from material evaporated from the contact surfaces.
  2. Arc Maintenance: This arc consists of ionized metal vapor and is maintained by the continued evaporation of metal from the contact surfaces.
  3. Current Zero Approaching: As the AC current approaches zero, the rate of metal evaporation decreases.
  4. Arc Extinction: At current zero, metal vapor production stops, and the remaining vapor condenses rapidly on the contact surfaces and the surrounding shield within microseconds.
  5. Dielectric Recovery: This rapid condensation creates a near-instantaneous recovery of dielectric strength between the contacts, preventing re-ignition of the arc even under high recovery voltage.

Primary Functions of VCB:

  • Circuit Protection: Rapid interruption of fault currents to protect equipment from damage
  • Operational Switching: Safe switching of loads, transformers, capacitor banks, and motors
  • Isolation: Providing visible isolation for maintenance personnel safety
  • Network Reconfiguration: Enabling changes to power system topology
  • Automatic Reclosing: Restoring service after temporary faults in overhead line systems
VCB Breaker Working Principle & Function
VCB Breaker Working Principle & Function

VCB Operation Process

Normal Closed Position

Contacts are closed, allowing current flow through the circuit. Spring mechanism is charged and ready.

Trip Command Initiation

Trip signal is received from protection relay, control system, or manual operation, energizing the trip coil.

Contact Separation

Trip coil releases the operating mechanism, causing the movable contact to separate from the fixed contact, creating a vacuum arc.

Arc Extinction

At current zero, the arc extinguishes as metal vapor condenses rapidly. Dielectric strength recovers within microseconds.

Open Position

Contacts remain separated, preventing current flow. Circuit is isolated and protected.

Reclosing (if applicable)

For automatic reclosing cycles, the close coil is energized, bringing the contacts back together to restore service.

VCB Breaker Parts Name & Structure

Main Components of a VCB

Vacuum Interrupter

The heart of the VCB, consisting of a vacuum chamber containing:

  • Fixed contact (stationary)
  • Moving contact (operated by mechanism)
  • Metallic bellows (maintains vacuum seal)
  • Ceramic insulator (provides electrical isolation)
  • Metal vapor condensing shield
Operating Mechanism

Provides the mechanical force to open and close the contacts:

  • Spring-charged mechanism
  • Motor for spring charging
  • Trip and close coils
  • Mechanical indicators
  • Manual operation provision
Support Insulators

Provide electrical isolation and mechanical support:

  • Post insulators
  • Phase barriers
  • Mounting structures
Control Panel

Contains electrical control and monitoring elements:

  • Auxiliary contacts
  • Operation counters
  • Control switches
  • Indicators and meters
  • Protection relay interfaces
Control Panel

Contains electrical control and monitoring elements:

  • Auxiliary contacts
  • Operation counters
  • Control switches
  • Indicators and meters
  • Protection relay interfaces
Enclosure

Houses and protects all components:

  • Metal housing
  • Safety interlocks
  • Earthing terminals
  • Ventilation (if required)
  • Access panels

VCB Breaker Symbol & Representation

Single-line Diagram Symbol

Used in electrical system schematics

Three-phase Representation

Used in detailed wiring diagrams

Contact Material Technology

Contact material selection is critical for VCB performance. The material must withstand high current interruption while minimizing contact erosion, welding, and chopping current effects.

Common Contact Materials
  • Copper-Chromium (CuCr) – Most common
  • Copper-Bismuth (CuBi)
  • Copper-Chromium-Bismuth (CuCrBi)
  • Tungsten-Copper-Silver alloys
Performance Characteristics
  • High electrical conductivity
  • Good thermal conductivity
  • Low chopping current tendency
  • High resistance to contact welding
  • Minimal contact erosion rate

Types of VCB Breakers

How many types of VCB are there?

While VCBs can be categorized in multiple ways (installation method, operating mechanism, environment, voltage rating, etc.), there are fundamentally three major types: fixed, withdrawable, and portable. When combined with the various operating mechanisms and voltage classes, there are approximately 12-15 distinct configurations of VCBs available in the market today.

Classification by Installation Method

Fixed Type VCB

Permanently installed in switchgear. Requires complete isolation of switchgear for maintenance.

Withdrawable Type VCB

Can be withdrawn from switchgear for maintenance or replacement without disrupting the entire system.

Portable VCB

Designed for temporary installations or emergency replacements. Less common but useful for specific applications.

Classification by Operating Mechanism

Spring Operated VCB

Uses pre-charged springs for storing mechanical energy required for opening and closing operations. Most common type.

Magnetic Actuator VCB

Employs electromagnetic forces for operation. Offers faster operating times and higher reliability for frequent operations.

Hydraulic Operated VCB

Uses hydraulic pressure for operation. Provides high operating force but requires more maintenance than other types.

Classification by Installation Environment

Indoor VCB

Designed for installation inside buildings or enclosures. IP40-IP54 protection rating. Less weather-resistant.

Outdoor VCB

Constructed for direct outdoor installation. Features IP55 or higher protection, enhanced insulation, and weather-resistant design.

Specialized Environmental VCB

Designed for extreme conditions like marine applications, high altitude, extreme temperatures, or highly corrosive environments.

GET IN TOUCH

Contact Us for Expert Solutions & Quotations

Reach out to discuss your specific requirements and discover how our vacuum circuit breaker solutions can enhance your electrical systems
TECHNICAL SPECIFICATIONS

VCB Technical Specs, Selection & Applications

Comprehensive guide to vacuum circuit breaker specifications, selection criteria, and application considerations

Understanding VCB Rating Parameters:

Rated Voltage Range: VCBs are commonly available for voltages from 3.6kV up to 40.5kV. For higher voltages (above 38kV), SF6 circuit breakers have traditionally been more common, though recent advances are pushing vacuum technology to higher voltage classes.

Current Rating Considerations: The current rating must be selected based on the maximum continuous load current expected in the circuit, with appropriate margin for future load growth. Common ratings range from 630A for distribution applications to 3150A for heavy industrial applications.

Breaking Capacity Selection: The breaking capacity (Isc) must exceed the maximum available fault current at the point of installation. This value is determined by network short-circuit studies and is critical for safe operation.

Vacuum Circuit Breaker Standard Ratings

VCB ratings are standardized according to international specifications including IEC 62271-100 and IEEE C37.04/C37.09. These standards define:

  • Preferred voltage values
  • Standard current ratings
  • Breaking capacity levels
  • Testing requirements
  • Endurance classifications

VCB Breaker Rating Calculation

Several key factors influence the calculation of required VCB ratings:

  • System voltage level with margin
  • Maximum continuous current with 25% margin
  • Maximum fault current from short-circuit studies
  • System X/R ratio for asymmetrical current factors
  • Altitude and ambient temperature derating
VCB Breaker Limit Considerations
  • Vacuum interrupter voltage withstand limitations
  • Contact thermal and mechanical stress limits
  • Operating mechanism force limitations
  • Economic considerations vs. SF6 technology

VCB Voltage & Current Range

VCB Voltage & Current Range

Standard Medium Voltage Range
1kv-45kv
Emerging High Voltage VCB
70.5kv-110kv

Vacuum circuit breakers excel in the medium voltage range (1kV to 38kV), with most common applications at 11kV, 24kV, and 33kV. Recent technological advances are extending their use into higher voltage ranges.

Common Voltage Classes

  • 3.6/4.16kV
  • 7.2kV
  • 12k
  • 17.5kV
  • 24kV
  • 36/40.5kV

We can calculate the HT full load current, IH from:

VCB Rating Chart

VCB Selection Guide & Applications

How do I choose my VCB rating?

Selecting the right VCB requires careful consideration of system parameters, operational requirements, and environmental conditions

1. System Voltage Considerations

Select a VCB with rated voltage equal to or higher than your system’s maximum operating voltage:

  • For 11kV system: Choose 12kV rated VCB
  • For 22kV system: Choose 24kV rated VCB
  • For 33kV system: Choose 36kV rated VCB

2. Current Rating Selection

The continuous current rating should exceed the maximum expected load current with margin for future growth:

Recommended rating = Maximum expected load current × 1.25

Example: For maximum load of 500A, choose at least 630A rated VCB

3. Short-Circuit Breaking Capacity

The breaking capacity must exceed the maximum calculated fault current at the installation point:

Breaking capacity > Maximum fault current at installation point

This requires a proper short-circuit study of the power system.

4. Environmental Factors

5. Operational Requirements

Professional Consultation

For optimal VCB selection, consult with our technical specialists who can analyze your specific requirements and recommend the most suitable solution.

Vacuum Circuit Breaker Applications

Where are vacuum circuit breakers used? Explore the diverse applications across industries

VCB used in Power Distribution
VCB used in Industrial Applications

Power Utility Applications

Substation Protection

Primary and backup protection for transformers and feeders in distribution substations

Distribution Network Switching

Sectionalizing and network reconfiguration in ring main systems

Capacitor Bank Protection

Switching and protection for power factor correction equipment

Industrial Applications

Motor Protection & Control

Protection for medium voltage motors in industrial facilities

Industrial Power Distribution

Main and feeder protection in manufacturing plants

Furnace Protection

Protection for electric arc furnaces and induction furnaces

Commercial & Infrastructure Applications

Commercial Buildings

Main power protection for high-rise buildings, shopping centers, and hospitals

Transportation Systems

Traction power substations for railways and metro systems

Data Centers

Critical power protection for data centers and IT infrastructure

Renewable Energy Applications

Solar Plants

Inverter protection and interconnection

Wind Farms

Generator and grid connection protection

Hydropower

Generator and auxiliary system protection

Advantages and Disadvantages of Vacuum Circuit Breakers

Substation Protection

Primary and backup protection for transformers and feeders in distribution substations

Long Service Life

Minimal contact erosion leads to longer service life (10,000+ operations without maintenance)

Environmentally Friendly

No SF6 gas (potent greenhouse gas) or oil, making VCBs more eco-friendly and safer

Compact Size

Vacuum interrupters are more compact than other technologies, allowing for smaller switchgear designs

No Maintenance Requirements

Sealed vacuum chamber eliminates need for insulating medium inspection or replacement

Voltage Limitation

Traditionally limited to medium voltage applications (up to 38kV), though technology is advancing

X-Ray Emission

High voltage vacuum can produce X-rays during operation (mitigated by proper design and shielding)

Current Chopping

Can cause current chopping in inductive circuits, potentially creating overvoltages (addressed with modern contact materials)

Manufacturing Complexity

Production of high-quality vacuum interrupters requires specialized technology and quality control

VCB Breaker Maintenance, Testing & Safety

VCB Maintenance Requirements

VCB Testing Procedures

Routine Testing
  • Contact resistance measurement
  • Insulation resistance testing
  • Operation timing tests
  • Trip and close coil current profile
  • Auxiliary contact operation verification
Advanced Testing
  • Dynamic contact resistance measurement
  • Vacuum integrity high-potential test
  • Mechanical operation analysis
  • Power factor / dissipation factor tests
  • Vibration analysis during operation

Routine Inspection

Visual inspection of external conditions, cleanliness, signs of overheating, and terminal connections

Mechanical Checks

Verification of operating mechanism, lubrication of moving parts (not the vacuum interrupter itself)

Electrical Testing

Insulation resistance measurement, contact resistance checking, and control circuit verification

Vacuum Integrity Check

High voltage withstand testing to verify vacuum integrity (typically after a specified number of operations)

TECHNOLOGY COMPARISON

SF6 Circuit Breakers & Comprehensive Comparison

Understanding the differences between vacuum and SF6 circuit breakers to make informed decisions for your power systems
SF6 Circuit Breaker Diagram​

SF6 Circuit Breaker Diagram

SF6 Gas Properties

  • Excellent dielectric strength
  • Superior arc quenching
  • Chemically inert in normal conditions
  • Non-flammable and non-toxic
  • Potent greenhouse gas (GWP 23,500)

SF6 (Sulfur Hexafluoride) circuit breakers use SF6 gas as the arc quenching and insulating medium. They have been widely used in high voltage applications due to their excellent insulating properties and arc interruption capabilities.

Key Characteristics of SF6 Circuit Breakers:

SF6 Circuit Breaker Types:

Puffer Type

Uses mechanical piston to compress and direct SF6 gas flow across the arc

Double Pressure Type

Uses two different pressure zones with gas flow from high to low pressure

Self-Blast Type

Uses arc energy to create pressure for gas flow without mechanical compression

Hybrid Designs

Combines features of different types for optimized performance

Major Drawback of SF6 Circuit Breakers

The most significant concern with SF6 circuit breakers is the environmental impact of SF6 gas. It is one of the most potent greenhouse gases, with:

  • Global Warming Potential (GWP) of 23,500 times that of CO₂ over a 100-year period
  • Atmospheric lifetime of approximately 3,200 years
  • Subject to increasing environmental regulations worldwide
  • Requires specialized handling, monitoring, and end-of-life disposal procedures

This environmental impact has led to increased interest in alternative technologies such as vacuum circuit breakers, especially for medium voltage applications.

Comparison: VCB vs. SF6 & ACB

FeatureVacuum Circuit Breaker (VCB)SF6 Circuit BreakerAir Circuit Breaker (ACB)
Arc Quenching MediumVacuumSF6 GasAir
Voltage Range1kV - 40.5kV (up to 72.5kV with new technology)Medium to high voltage (12kV to 800kV)Low voltage (up to 1kV)
Current RangeUp to 4000AUp to 6300AUp to 6300A
Breaking CapacityUp to 63kAUp to 80kAUp to 100kA
Arc Extinction TimeFirst current zero (extremely fast)2-3 half cyclesMultiple half cycles
Contact WearMinimalModerateHigh
Maintenance RequirementsVery low (sealed for life)Moderate (gas monitoring required)High (regular inspection and maintenance)
Environmental ImpactLow (no greenhouse gas)High (SF6 is potent greenhouse gas)Moderate
Size/CompactnessVery compactCompactBulky
Operational Life20-30 years20-25 years15-20 years
CostModerateHighLow to moderate
Special RequirementsNoneGas handling, leak detection, low temperature heatingArc chutes, regular contact maintenance
Common ApplicationsMedium voltage distribution, industrial applicationsHigh voltage transmission, some MV applicationsLow voltage distribution, building protection
Future OutlookGrowing market share due to environmental benefitsDeclining due to environmental regulationsStable for LV applications

VCB vs. ACB

The primary difference between VCB (Vacuum Circuit Breaker) and ACB (Air Circuit Breaker) is their voltage application range and arc quenching medium:

VCB vs. SF6

The primary difference between VCB (Vacuum Circuit Breaker) and ACB (Air Circuit Breaker) is their voltage application range and arc quenching medium:

Industry Trend

The primary difference between VCB (Vacuum Circuit Breaker) and ACB (Air Circuit Breaker) is their voltage application range and arc quenching medium:

COMMON QUESTIONS

Frequently Asked Questions

Find answers to common questions about vacuum circuit breakers, specifications, and applications
Q: What is a VCB breaker? / What is a VCB circuit breaker? / What are vacuum circuit breakers?

A: A VCB (Vacuum Circuit Breaker) is an electrical switch that uses a vacuum as the arc quenching medium to interrupt electrical current. When the contacts inside the VCB separate during a fault or switching operation, an electric arc is formed. The high dielectric strength and rapid recovery characteristics of the vacuum quickly extinguish this arc, safely interrupting the current flow. They are primarily used in medium voltage power systems for protection and switching.

Q: How does a VCB breaker work? / How to work VCB breaker?

A: A VCB works by separating its electrical contacts within a sealed vacuum interrupter.

  1. Normal Operation: The contacts are closed, allowing current to flow.
  2. Fault Detection/Trip Signal: When a fault (like a short circuit or overload) occurs, or a manual/remote trip command is given, the VCB’s operating mechanism is activated.
  3. Contact Separation: The mechanism (often spring-charged or magnetically actuated) rapidly pulls the moving contact away from the fixed contact inside the vacuum chamber.
  4. Arc Formation: As the contacts separate, an arc is drawn between them, consisting of vaporized contact material.
  5. Arc Extinction: The high vacuum environment has excellent insulating properties. The metal vapor from the arc quickly disperses and condenses on the cool surfaces within the interrupter. At the next current zero (when AC current naturally passes through zero), the dielectric strength of the vacuum between the contacts rapidly recovers, preventing the arc from re-igniting and thus extinguishing it. This process isolates the faulty part of the circuit.
Q: Where are vacuum circuit breakers used?

A: Vacuum Circuit Breakers are predominantly used in medium voltage (MV) applications, typically ranging from 3.3kV to 38kV (though some special designs can go higher). Common applications include:

  • Power distribution substations
  • Industrial plants and manufacturing facilities
  • Power generation stations (for auxiliary supplies)
  • Railway electrification systems
  • Capacitor bank switching
  • Controlling large motors and arc furnaces
  • Renewable energy installations (e.g., wind and solar farms)
Q: What is the VCB rating for 33KV?

A: For a 33kV system, VCBs are typically designed with a rated voltage of 36kV (which is the next standard highest system voltage category as per IEC standards). Key ratings for a 33kV VCB include:

  • Rated Voltage: 36kV
  • Rated Normal Current: Common values include 630A, 1250A, 1600A, 2500A, or higher, depending on the load.
  • Rated Short-Circuit Breaking Current: Typically ranges from 25kA to 40kA, depending on the fault level of the system. Always refer to the specific manufacturer’s datasheet for precise ratings for a particular model.
Q: Which circuit breaker is used for 33KV?

A: Vacuum Circuit Breakers (VCBs) are very commonly and widely used for 33kV applications. Their reliability, long operational life, minimal maintenance requirements, and environmental friendliness make them a preferred choice for this voltage level. SF6 circuit breakers can also be used but VCBs are often favored in many MV scenarios.

Q: What is the limit of a VCB breaker?

A: The “limit” of a VCB breaker can refer to several of its rated parameters, which define its operational boundaries:

  • Voltage Limit: Standard VCBs are available up to 38kV/40.5kV, with some specialized designs for higher voltages.
  • Current Carrying Limit (Rated Normal Current): This is the maximum continuous current it can carry without overheating, which can go up to 4000A or more for specific designs.
  • Interrupting Limit (Rated Short-Circuit Breaking Current): This is the maximum fault current it can safely interrupt, typically up to 50kA or 63kA for some MV VCBs.
  • Mechanical/Electrical Endurance: Limits on the number of opening/closing operations. The specific limits depend on the design, intended application, and manufacturer.
Q: Who is the manufacturer of 33KV VCB?

A: Choosing the correct VCB rating involves considering several critical system parameters:

  1. System Voltage: Select a VCB with a rated voltage equal to or higher than the highest operating voltage of your system (e.g., for an 11kV system, a 12kV rated VCB is used).
  2. Rated Normal Current: The VCB’s continuous current rating must be greater than the maximum continuous load current it is expected to carry.
  3. Short-Circuit Breaking Current: The VCB must be able to safely interrupt the maximum prospective fault current at the point of installation. This requires a fault level calculation for your system.
  4. Short-Time Withstand Current: The VCB should be able to withstand the thermal and dynamic stresses of the fault current for a specified duration (e.g., 1 or 3 seconds).
  5. Operating Duty Cycle: The sequence and frequency of expected operations.
  6. Environmental Conditions: Such as ambient temperature, altitude, and humidity. It’s always recommended to consult relevant standards (like IEC or ANSI/IEEE) and work with experienced engineers or the VCB manufacturer.
Q: How many amps is a VCB breaker?

A: The amperage, or rated normal current, of a VCB breaker varies widely depending on its design and the application it’s intended for. For medium voltage VCBs, common current ratings can range from 400A, 630A, 800A, 1250A, 1600A, 2000A, 2500A, 3150A, up to 4000A or even higher for specialized applications.

Q: How many types of VCB are there?

A: VCBs can be categorized based on several criteria:

  1. By Installation Environment:
    • Indoor VCBs: Designed for installation within buildings or enclosed switchgear.
    • Outdoor VCBs: Designed to withstand outdoor environmental conditions (e.g., pole-mounted or in outdoor substations).
  2. By Mounting Type (primarily for indoor switchgear):
    • Fixed Type: Bolted directly into the switchgear panel.
    • Withdrawable Type: Mounted on a truck or cassette, allowing them to be easily racked in/out for maintenance and isolation.
  3. By Operating Mechanism:
    • Spring-Operated Mechanism: Uses energy stored in charged springs.
    • Magnetic Actuator Mechanism: Uses electromagnetic force for operation. While the core vacuum interrupter technology is the same, these classifications differentiate VCBs based on their application and construction.
Q: Which circuit breaker is used for 11KV?

A: Vacuum Circuit Breakers (VCBs) are overwhelmingly the most common and preferred type of circuit breaker for 11kV (and 12kV rated voltage) systems. Their excellent performance, reliability, compact size, long electrical life, and low maintenance requirements make them an ideal choice for 11kV power distribution networks, industrial applications, and transformer protection.

OUR ADVANTAGES

Why Choose Us as Your VCB Supplier

Experience the difference of working with a dedicated manufacturer committed to quality, innovation, and customer satisfaction

Specialized Manufacturing Experience

With over 10 years dedicated to manufacturing electrical equipment, our expertise in VCB technology ensures products of exceptional quality and reliability. Our specialized knowledge translates to superior solutions for your power systems.

Established in 2013

Certified Quality Assurance

Every VCB we produce undergoes rigorous testing to international standards, ensuring outstanding performance and safety. Our quality management system guarantees consistent excellence in every product we deliver.

ISO 9001 Certified

Customized Solutions

We understand that different applications have unique requirements. Our engineering team works closely with customers to develop tailored VCB solutions that precisely match your technical specifications and operational needs.

Tailored to Your Needs

Comprehensive Technical Support

Our support doesn't end with delivery. Our expert team provides comprehensive assistance throughout the entire product lifecycle – from selection advice and installation guidance to maintenance support and troubleshooting.

Lifetime Technical Assistance

Global Service Network

Our products are trusted by clients worldwide. With an established international distribution network, we provide efficient logistics and localized support to ensure prompt delivery and service regardless of your location.

Serving Customers Worldwide

Competitive Pricing

As a direct manufacturer with optimized production processes, we offer exceptional value without compromising on quality. Our efficient operations and economies of scale allow us to provide competitive pricing for premium VCB products.

Excellent Value Proposition

Our Manufacturing Excellence

vacuum circuit breaker manufacturer 02

Our Manufacturing Excellence

At Zhejiang Dianji Power, we’ve invested in state-of-the-art production facilities and rigorous quality control processes to ensure the highest standards of manufacturing excellence. Our comprehensive approach encompasses every aspect of the production process, from raw material selection to final testing.

Advanced Production Technology

Modern CNC machinery and automated assembly lines ensure precision manufacturing

Experienced Engineering Team

Skilled engineers with decades of combined experience in VCB design and manufacturing

Comprehensive Testing Laboratory

Equipped with high-voltage testing facilities, mechanical endurance testers, and environmental chambers

Strict Quality Control

100% product testing with detailed inspection protocols and traceability