35kv 36 kv vacuum circuit breaker
Engineered for superior protection and control in 35kv 36kV (40.5kV rated) medium voltage networks. The ZN85-40.5 (3AV3) ensures unparalleled reliability for critical power infrastructure.
Please Write your message, ask for price, we will reply you soon, thanks
Uncompromising Protection for Demanding 35kv 36kV Applications
The ZN85-40.5 (3AV3) series indoor high voltage vacuum circuit breaker represents a pinnacle of joint engineering excellence, developed in collaboration with the prestigious Xi’an High Voltage Apparatus Research Institute. Designed specifically for three-phase AC 50Hz indoor systems operating at a nominal voltage of 36kV (within the 40.5kV rated voltage class), this VCB is the cornerstone of safe and efficient power distribution.
It is meticulously engineered to interrupt load currents, overload currents, and critical short-circuit currents, thereby safeguarding valuable assets in industrial complexes, mining operations, power generation facilities, and substations. Its robust design and proven technology make it exceptionally suitable for applications demanding frequent switching operations, offering extended operational life and minimized maintenance downtime.
Why Choose the ZN85-40.5?
- Proven Reliability: Co-developed with leading research institutes.
- Superior Interruption: Handles diverse current conditions effectively.
- High Endurance: Ideal for frequent switching, ensuring longevity.
- Safety Focused: Designed for secure operation in high-voltage environments.
- Optimized Footprint: Composite insulation allows for compact switchgear design.
Working Principle Explained
At the heart of the ZN85-40.5 lies its sophisticated vacuum interrupter (VI) technology. Vacuum is an ideal dielectric medium, offering rapid recovery of dielectric strength after arc extinction. When the contacts separate under load or fault conditions, an arc is drawn between them within the hermetically sealed VI.
The key advantages of this technology include:
Superior Arc Quenching: The high vacuum (typically 10-4 Pa or better) ensures that the plasma arc, composed of vaporized contact material, rapidly disperses and condenses on metallic shields within the interrupter. This results in swift arc extinction at the first current zero.
Minimal Contact Erosion: Optimized contact materials (e.g., CuCr alloys) and advanced contact geometries (like Axial Magnetic Field – AMF or Radial Magnetic Field – RMF contacts) minimize arc energy and ensure controlled arc movement, significantly reducing contact wear and extending electrical life. The ZN85-40.5 can be equipped with VIs employing longitudinal magnetic field principles for low current chopping and excellent asymmetrical breaking.
Environmentally Sound: Vacuum interrupters are environmentally benign, containing no SF6 or other greenhouse gases. This simplifies handling, disposal, and reduces environmental impact.
Maintenance-Free Interrupters: The sealed-for-life VIs require no re-filling or maintenance of the interrupting medium, drastically reducing lifecycle costs.
Innovative Structural Design for Enhanced Performance
Integrated Pole-Mounted Structure
The ZN85-40.5 features an intelligent layout with arc-extinguishing chambers (vacuum interrupters) positioned above the operating mechanism. This “pole-over-mechanism” design simplifies assembly, enhances mechanical stability, and facilitates easier access for commissioning and inspection, contributing to streamlined maintenance routines.
Advanced Composite Insulation
Employing a sophisticated composite insulation system that combines the dielectric strengths of air and high-performance organic insulating materials, the VCB achieves excellent insulation coordination. This allows for a more compact physical footprint without compromising electrical safety or performance, enabling space-efficient switchgear designs.
High-Reliability Spring Operating Mechanism
The breaker is equipped with a robust and simplified spring-charged operating mechanism. Engineered for consistency and high mechanical endurance, it is rated for 10,000 maintenance-free mechanical operations, ensuring long-term reliability and reducing the need for frequent servicing. The design incorporates a lead screw propulsion system that provides smooth, effort-saving, and stable operation with excellent self-locking characteristics.
Designed for Demanding Operating Environments
The ZN85-40.5 is engineered to perform reliably under a range of standard indoor conditions. Adherence to these parameters ensures optimal performance and longevity:
Altitude:
Not exceeding 2000 meters. Performance at higher altitudes may require de-rating or special considerations.
Relative Humidity:
Daily average ≤ 95%; Monthly average ≤ 90%. Non-condensing environment is crucial to prevent insulation degradation.
Ambient Temperature:
Operational range from -15°C to +40°C. Temperature extremes may affect lubrication and material properties.
Relative Humidity:
Daily average ≤ 95%; Monthly average ≤ 90%. Non-condensing environment is crucial to prevent insulation degradation.
Important: The VCB must be installed in locations free from fire or explosion hazards, excessive mechanical vibrations, chemical corrosion, and severe pollution that could compromise its insulation integrity or operational mechanisms. For conditions beyond these specifications, please consult with our engineering team for customized solutions or applicability assessment.
Key Technical Parameters
| No. | Parameter Description | Unit | Value / Range | |
|---|---|---|---|---|
| 1 | Rated Voltage (System Nominal) | kV | 36 (Suitable for 40.5kV Class Systems) | |
| 2 | Rated Frequency | Hz | 50 | |
| 3 | Rated Normal Current | A | 1250, 1600, 2000 (Specify on order) | |
| 4 | Rated Short-circuit Breaking Current (Isc) | kA | 25, 31.5 (Specify on order) | |
| 5 | Rated Short-time Withstand Current (Icw) | kA | 25, 31.5 (for 4s) | |
| 6 | Rated Peak Withstand Current (Ip) | kApeak | 63, 80 | |
| 7 | Rated Short-circuit Making Current (Ima) | kApeak | 63, 80 | |
| 8 | Rated Short-circuit Duration (tk) | s | 4 | |
| 9 | 1-minute Power Frequency Withstand Voltage (RMS) | kV | 95 (Phase-to-earth, Phase-to-phase, Across open contacts) | |
| 10 | Lightning Impulse Withstand Voltage (Peak) | kVpeak | 185 (Phase-to-earth, Phase-to-phase, Across open contacts) | |
| 11 | Total Breaking Time (at rated Isc) | ms | <80 (Typically 40-60ms) | |
| 12 | Rated Number of Short-circuit Breaking Operations | Operations | 20 | |
| 13 | Rated Single Capacitor Bank Breaking Current | A | 630 | |
| 14 | Rated Back-to-back Capacitor Bank Breaking Current | A | 400 | |
| 15 | Rated Operating Voltage for Mechanism | V | DC: 110, 220; AC: 110, 220 (Specify on order) | |
| 16 | Mechanical Endurance (Class M2) | Operations | 10,000 | |
| 17 | Rated Operating Sequence | - | O - 0.3s - CO - 180s - CO | |
Disconnector Switch Application Scenarios
Distribution Substations
Feeder protection, transformer incomers.
Industrial Plants
Powering heavy machinery, critical processes.
Renewable Energy
Wind farms, solar power plant collection circuits.
Railway Traction
Power supply for electrified rail lines.
Commercial Buildings
Large complexes, data centers.
MV Switchgear Assemblies
Integral part of metal-clad and metal-enclosed switchgear.
Installation, Safety, and Compliance
Commitment to Safety and Standards
- Inherent Safety: Vacuum interruption technology eliminates risks associated with flammable or pressurized gases.
- Mechanical Interlocks: Robust interlocking systems prevent maloperation in withdrawable units (e.g., cannot rack in/out if closed, cannot close if not fully racked in/out or in test position).
- Visual Indicators: Clear indication of breaker status (Open/Closed) and spring mechanism (Charged/Discharged).
- Standards Compliance: Designed and type-tested in accordance with relevant national (GB) and international standards such as IEC 62271-100. Specific compliance certificates available upon request.
- Quality Manufacturing: Produced under ISO 9001 certified quality management systems ensuring consistent product quality and reliability.
Dimensional Data & Integration
The ZN85-40.5 VCB is available in fixed and withdrawable (handcart type) versions for seamless integration into KYN61-40.5 or similar type-tested switchgear panels. Detailed outline drawings, installation dimensions, and schematic diagrams of the operating mechanism are provided in comprehensive technical documentation.
Key mechanism components typically include: opening/closing springs, main shaft, pole lever arms, transmission linkages, contact springs, and rod end bearings, all engineered for precise and reliable operation.
Ready to Discuss Your 24kV VCB Needs?
Our experts are here to help you select the perfect vacuum circuit breaker solution for your project. Contact us today for technical support, pricing, or a customized quote.
Request a Quote
Fill out the form below with your project details, and our sales team will provide a customized quotation tailored to your specific requirements within 24 hours.
Frequently Asked Questions
A: A 24kV Vacuum Circuit Breaker (VCB) is an electrical switch designed to protect your medium-voltage equipment (operating at 24,000 volts) by safely interrupting electrical currents during normal operations and, more importantly, under fault conditions like short circuits. You need it to ensure the safety of your personnel, prevent damage to expensive equipment, and maintain a reliable power supply.
A: At the 24kV level, VCBs offer significant advantages:
1. **Environmentally Friendly:** They use a vacuum as the interrupting medium, which has no greenhouse gas emissions, unlike SF6 gas.
2. **Low Maintenance:** The sealed vacuum interrupters require virtually no maintenance on the arc-quenching medium itself, leading to lower operational costs.
3. **High Reliability & Long Life:** They have a simple, robust design, capable of many operations and a long service life.
4. **Compact Size:** VCBs often allow for more compact switchgear designs.
5. **Safety:** No risk of SF6 gas leakage or handling issues.
A: A well-maintained 24kV VCB typically has a mechanical lifespan of 20,000 to 30,000 operations and an electrical service life of 20-30 years, depending on the specific model and operating conditions. The vacuum interrupter itself is designed to last the life of the breaker.
A: VCBs are known for their minimal maintenance requirements. Periodic checks typically involve visual inspections, cleaning, lubrication of the operating mechanism (if spring-operated), and checking electrical connections. The vacuum interrupter itself is sealed for life and doesn’t require internal maintenance. Always follow the manufacturer’s specific maintenance schedule.
A: Vacuum interrupter technology is very mature and highly reliable. The vacuum is maintained in a hermetically sealed ceramic or glass envelope. While direct monitoring is not always standard, manufacturers perform rigorous testing. For critical applications or during major maintenance, a high-voltage withstand test across the open contacts can verify the vacuum integrity. Some specialized VCBs might offer vacuum monitoring features.
A: Yes, 24kV VCBs are extremely versatile and are widely used in distribution substations, industrial power systems, renewable energy generation (wind/solar farms), railway electrification, and large commercial buildings. We can help you select the right model based on your specific load, fault level, and environmental conditions.
A: To help us recommend the best VCB, please provide:
1. Rated Voltage (e.g., 24kV)
2. Rated Continuous Current (e.g., 630A, 1250A, 2500A)
3. Rated Short-Circuit Breaking Current (e.g., 25kA, 31.5kA)
4. Operating Mechanism Type (e.g., spring-charged, magnetic actuator) and its control voltage.
5. Installation Type (e.g., fixed, withdrawable for switchgear).
6. Any specific environmental conditions or dimensional constraints.
A: Installation should be performed by qualified personnel familiar with medium-voltage equipment. It involves secure mounting, correct power and control wiring, and proper grounding. Commissioning includes functional checks of the operating mechanism and control circuits. We provide detailed installation manuals, and can offer support services if needed.
A: Our VCBs are designed and type-tested according to international standards like IEC 62271-100. They typically come with type test reports from accredited laboratories, confirming their performance for rated voltage, current, breaking capacity, and endurance. Specific certifications can be provided upon request.
A: We offer comprehensive after-sales support, including readily available spare parts for common components (like operating mechanisms, control coils) and technical assistance. Our goal is to ensure your VCB operates reliably throughout its service life. Please contact our support team for any assistance.
Decoding Transformer Nameplates: Complete Guide to Ratings (kVA, Voltage, Impedance)
Decoding Transformer Nameplates: Complete Guide to Ratings (kVA, Voltage, Impedance) Master the critical information hidden in plain sight on every power transformer nameplate 💡 Engineering Insight from the Field As a senior electrical engineer, I...
Read MorePower Transformer vs. Distribution Transformer: 7 Key Differences
Power Transformer vs. Distribution Transformer: Key Differences and Application Analysis Author: ElecBase Engineering Team | Last Updated: January 2025 Reading Time: 8 minutes | Technical Level: Intermediate to Advanced Table of Contents Introduction: Understanding the...
Read MoreThe Ultimate Guide to Step-Up Power Transformers
The Ultimate Guide to Step-Up Power Transformers The Ultimate Guide to Step-Up Power Transformers Step-up transformers are foundational pillars of modern electrical grids, yet their monumental importance is often overlooked. As the powerful gateways between...
Read MoreStep-Down Transformer 101: The Ultimate Guide to How They Power Your World
Step-Down Transformer 101: The Ultimate Guide to How They Power Your World From the power grid to your wall socket, discover the unsung hero that makes our modern lives possible. This guide covers everything an...
Read MoreWhat Are the Types of SF6 Circuit Breakers?
What Are the Types of SF6 Circuit Breakers? Choosing the right SF6 circuit breaker can be confusing. Making the wrong choice can lead to operational issues or safety risks. Understanding the core classifications simplifies the...
Read More