35kv 36 kv vacuum circuit breaker

Engineered for superior protection and control in 35kv 36kV (40.5kV rated) medium voltage networks. The ZN85-40.5 (3AV3) ensures unparalleled reliability for critical power infrastructure.

Home / Vacuum Circuit Breakers / 35kv 36 kv vacuum circuit breaker

Uncompromising Protection for Demanding 35kv 36kV Applications

The ZN85-40.5 (3AV3) series indoor high voltage vacuum circuit breaker represents a pinnacle of joint engineering excellence, developed in collaboration with the prestigious Xi’an High Voltage Apparatus Research Institute. Designed specifically for three-phase AC 50Hz indoor systems operating at a nominal voltage of 36kV (within the 40.5kV rated voltage class), this VCB is the cornerstone of safe and efficient power distribution.

It is meticulously engineered to interrupt load currents, overload currents, and critical short-circuit currents, thereby safeguarding valuable assets in industrial complexes, mining operations, power generation facilities, and substations. Its robust design and proven technology make it exceptionally suitable for applications demanding frequent switching operations, offering extended operational life and minimized maintenance downtime.

Why Choose the ZN85-40.5?

  • Proven Reliability: Co-developed with leading research institutes.
  • Superior Interruption: Handles diverse current conditions effectively.
  • High Endurance: Ideal for frequent switching, ensuring longevity.
  • Safety Focused: Designed for secure operation in high-voltage environments.
  • Optimized Footprint: Composite insulation allows for compact switchgear design.
36 kv vacuum circuit breaker

Working Principle Explained

At the heart of the ZN85-40.5 lies its sophisticated vacuum interrupter (VI) technology. Vacuum is an ideal dielectric medium, offering rapid recovery of dielectric strength after arc extinction. When the contacts separate under load or fault conditions, an arc is drawn between them within the hermetically sealed VI.

The key advantages of this technology include:

36 kv vacuum circuit breaker diagram(2)

Superior Arc Quenching: The high vacuum (typically 10-4 Pa or better) ensures that the plasma arc, composed of vaporized contact material, rapidly disperses and condenses on metallic shields within the interrupter. This results in swift arc extinction at the first current zero.

Minimal Contact Erosion: Optimized contact materials (e.g., CuCr alloys) and advanced contact geometries (like Axial Magnetic Field – AMF or Radial Magnetic Field – RMF contacts) minimize arc energy and ensure controlled arc movement, significantly reducing contact wear and extending electrical life. The ZN85-40.5 can be equipped with VIs employing longitudinal magnetic field principles for low current chopping and excellent asymmetrical breaking.

Environmentally Sound: Vacuum interrupters are environmentally benign, containing no SF6 or other greenhouse gases. This simplifies handling, disposal, and reduces environmental impact.

Maintenance-Free Interrupters: The sealed-for-life VIs require no re-filling or maintenance of the interrupting medium, drastically reducing lifecycle costs.

Innovative Structural Design for Enhanced Performance

Integrated Pole-Mounted Structure

The ZN85-40.5 features an intelligent layout with arc-extinguishing chambers (vacuum interrupters) positioned above the operating mechanism. This “pole-over-mechanism” design simplifies assembly, enhances mechanical stability, and facilitates easier access for commissioning and inspection, contributing to streamlined maintenance routines.

Advanced Composite Insulation

Employing a sophisticated composite insulation system that combines the dielectric strengths of air and high-performance organic insulating materials, the VCB achieves excellent insulation coordination. This allows for a more compact physical footprint without compromising electrical safety or performance, enabling space-efficient switchgear designs.

High-Reliability Spring Operating Mechanism

The breaker is equipped with a robust and simplified spring-charged operating mechanism. Engineered for consistency and high mechanical endurance, it is rated for 10,000 maintenance-free mechanical operations, ensuring long-term reliability and reducing the need for frequent servicing. The design incorporates a lead screw propulsion system that provides smooth, effort-saving, and stable operation with excellent self-locking characteristics.

Designed for Demanding Operating Environments

The ZN85-40.5 is engineered to perform reliably under a range of standard indoor conditions. Adherence to these parameters ensures optimal performance and longevity:

Altitude:

Not exceeding 2000 meters. Performance at higher altitudes may require de-rating or special considerations.

Relative Humidity:

Daily average ≤ 95%; Monthly average ≤ 90%. Non-condensing environment is crucial to prevent insulation degradation.

Ambient Temperature:

Operational range from -15°C to +40°C. Temperature extremes may affect lubrication and material properties.

Relative Humidity:

Daily average ≤ 95%; Monthly average ≤ 90%. Non-condensing environment is crucial to prevent insulation degradation.

Important: The VCB must be installed in locations free from fire or explosion hazards, excessive mechanical vibrations, chemical corrosion, and severe pollution that could compromise its insulation integrity or operational mechanisms. For conditions beyond these specifications, please consult with our engineering team for customized solutions or applicability assessment.

Key Technical Parameters

No.Parameter DescriptionUnitValue / Range
1Rated Voltage (System Nominal)kV36 (Suitable for 40.5kV Class Systems)
2Rated FrequencyHz50
3Rated Normal CurrentA1250, 1600, 2000 (Specify on order)
4Rated Short-circuit Breaking Current (Isc)kA25, 31.5 (Specify on order)
5Rated Short-time Withstand Current (Icw)kA25, 31.5 (for 4s)
6Rated Peak Withstand Current (Ip)kApeak63, 80
7Rated Short-circuit Making Current (Ima)kApeak63, 80
8Rated Short-circuit Duration (tk)s4
91-minute Power Frequency Withstand Voltage (RMS)kV95 (Phase-to-earth, Phase-to-phase, Across open contacts)
10Lightning Impulse Withstand Voltage (Peak)kVpeak185 (Phase-to-earth, Phase-to-phase, Across open contacts)
11Total Breaking Time (at rated Isc)ms<80 (Typically 40-60ms)
12Rated Number of Short-circuit Breaking OperationsOperations20
13Rated Single Capacitor Bank Breaking CurrentA630
14Rated Back-to-back Capacitor Bank Breaking CurrentA400
15Rated Operating Voltage for MechanismVDC: 110, 220; AC: 110, 220 (Specify on order)
16Mechanical Endurance (Class M2)Operations10,000
17Rated Operating Sequence-O - 0.3s - CO - 180s - CO

Disconnector Switch Application Scenarios

Disconnector Switch In Power Transmission

Distribution Substations

Feeder protection, transformer incomers.

Disconnector Switch In Distribution Networks

Industrial Plants

Powering heavy machinery, critical processes.

Disconnector Switch In Renewable Energy

Renewable Energy

Wind farms, solar power plant collection circuits.

Disconnector Switch In Railway Electrification

Railway Traction

Power supply for electrified rail lines.

Commercial Buildings

Large complexes, data centers.

MV Switchgear Assemblies

MV Switchgear Assemblies

Integral part of metal-clad and metal-enclosed switchgear.

Installation, Safety, and Compliance

Commitment to Safety and Standards

  • Inherent Safety: Vacuum interruption technology eliminates risks associated with flammable or pressurized gases.
  • Mechanical Interlocks: Robust interlocking systems prevent maloperation in withdrawable units (e.g., cannot rack in/out if closed, cannot close if not fully racked in/out or in test position).
  • Visual Indicators: Clear indication of breaker status (Open/Closed) and spring mechanism (Charged/Discharged).
  • Standards Compliance: Designed and type-tested in accordance with relevant national (GB) and international standards such as IEC 62271-100. Specific compliance certificates available upon request.
  • Quality Manufacturing: Produced under ISO 9001 certified quality management systems ensuring consistent product quality and reliability.

Dimensional Data & Integration

The ZN85-40.5 VCB is available in fixed and withdrawable (handcart type) versions for seamless integration into KYN61-40.5 or similar type-tested switchgear panels. Detailed outline drawings, installation dimensions, and schematic diagrams of the operating mechanism are provided in comprehensive technical documentation.

Key mechanism components typically include: opening/closing springs, main shaft, pole lever arms, transmission linkages, contact springs, and rod end bearings, all engineered for precise and reliable operation.

Ready to Discuss Your 24kV VCB Needs?

Our experts are here to help you select the perfect vacuum circuit breaker solution for your project. Contact us today for technical support, pricing, or a customized quote.

Request a Quote

Fill out the form below with your project details, and our sales team will provide a customized quotation tailored to your specific requirements within 24 hours.

COMMON QUESTIONS

Frequently Asked Questions

Q: What exactly is a 24kV Vacuum Circuit Breaker and why do I need one?

A: A 24kV Vacuum Circuit Breaker (VCB) is an electrical switch designed to protect your medium-voltage equipment (operating at 24,000 volts) by safely interrupting electrical currents during normal operations and, more importantly, under fault conditions like short circuits. You need it to ensure the safety of your personnel, prevent damage to expensive equipment, and maintain a reliable power supply.

Q: What are the main advantages of using a Vacuum Circuit Breaker compared to other types, like SF6 breakers, at 24kV?

A: At the 24kV level, VCBs offer significant advantages:
1. **Environmentally Friendly:** They use a vacuum as the interrupting medium, which has no greenhouse gas emissions, unlike SF6 gas.
2. **Low Maintenance:** The sealed vacuum interrupters require virtually no maintenance on the arc-quenching medium itself, leading to lower operational costs.
3. **High Reliability & Long Life:** They have a simple, robust design, capable of many operations and a long service life.
4. **Compact Size:** VCBs often allow for more compact switchgear designs.
5. **Safety:** No risk of SF6 gas leakage or handling issues.

Q: How long can I expect a 24kV VCB to last?

A: A well-maintained 24kV VCB typically has a mechanical lifespan of 20,000 to 30,000 operations and an electrical service life of 20-30 years, depending on the specific model and operating conditions. The vacuum interrupter itself is designed to last the life of the breaker.

Q: How much maintenance do these VCBs actually require?

A: VCBs are known for their minimal maintenance requirements. Periodic checks typically involve visual inspections, cleaning, lubrication of the operating mechanism (if spring-operated), and checking electrical connections. The vacuum interrupter itself is sealed for life and doesn’t require internal maintenance. Always follow the manufacturer’s specific maintenance schedule.

Q: Is the vacuum inside the interrupter reliable? How do I know it's still good?

A: Vacuum interrupter technology is very mature and highly reliable. The vacuum is maintained in a hermetically sealed ceramic or glass envelope. While direct monitoring is not always standard, manufacturers perform rigorous testing. For critical applications or during major maintenance, a high-voltage withstand test across the open contacts can verify the vacuum integrity. Some specialized VCBs might offer vacuum monitoring features.

Q: Are these 24kV VCBs suitable for my specific application (e.g., industrial plant, substation, renewable energy project)?

A: Yes, 24kV VCBs are extremely versatile and are widely used in distribution substations, industrial power systems, renewable energy generation (wind/solar farms), railway electrification, and large commercial buildings. We can help you select the right model based on your specific load, fault level, and environmental conditions.

Q: What key information do I need to provide to get a quote or select the right 24kV VCB?

A: To help us recommend the best VCB, please provide:
1. Rated Voltage (e.g., 24kV)
2. Rated Continuous Current (e.g., 630A, 1250A, 2500A)
3. Rated Short-Circuit Breaking Current (e.g., 25kA, 31.5kA)
4. Operating Mechanism Type (e.g., spring-charged, magnetic actuator) and its control voltage.
5. Installation Type (e.g., fixed, withdrawable for switchgear).
6. Any specific environmental conditions or dimensional constraints.

Q: How complex is the installation and commissioning process?

A: Installation should be performed by qualified personnel familiar with medium-voltage equipment. It involves secure mounting, correct power and control wiring, and proper grounding. Commissioning includes functional checks of the operating mechanism and control circuits. We provide detailed installation manuals, and can offer support services if needed.

Q: What kind of testing and certifications do your 24kV VCBs have?

A: Our VCBs are designed and type-tested according to international standards like IEC 62271-100. They typically come with type test reports from accredited laboratories, confirming their performance for rated voltage, current, breaking capacity, and endurance. Specific certifications can be provided upon request.

Q: What happens if I need spare parts or technical support after purchase?

A: We offer comprehensive after-sales support, including readily available spare parts for common components (like operating mechanisms, control coils) and technical assistance. Our goal is to ensure your VCB operates reliably throughout its service life. Please contact our support team for any assistance.

Related Blogs

The Ultimate Guide to Step-Up Power Transformers

The Ultimate Guide to Step-Up Power Transformers The Ultimate Guide to Step-Up Power Transformers Step-up transformers are foundational pillars of modern electrical grids, yet their monumental importance is often overlooked. As the powerful gateways between...

Read More

Request an instant quote

JOE WEI

Technical support-Your trust partner in China