In the demanding world of medium-voltage power distribution, reliability, safety, and operational efficiency are paramount. The VS1-24 Indoor High Voltage Vacuum Circuit Breaker is engineered to meet these critical needs. Operating as a three-phase AC 50Hz switchgear component for 24kV power systems, the VS1-24 serves as a vital protection and control unit for power grid equipment and industrial/mining enterprise power installations.
Its robust design makes it particularly suitable for environments requiring frequent operation under rated working current or those needing to reliably interrupt short-circuit currents multiple times, ensuring the longevity and safety of your electrical infrastructure.
Why Choose the VS1-24 Vacuum Circuit Breaker?
- Superior Interruption Capability: Utilizes advanced vacuum interrupter technology, renowned for its excellent arc quenching properties, fast recovery of dielectric strength, and ability to handle numerous short-circuit interruptions without significant degradation.
- Designed for Frequent Operations: Engineered for applications demanding repeated switching cycles under normal load conditions, making it ideal for dynamic industrial processes.
- Integrated and Versatile Design: The VS1-24 features an innovative integrated design of the operating mechanism and the circuit breaker body. This streamlined construction allows it to function effectively as a fixed installation unit or to be seamlessly equipped with a dedicated trolley mechanism, transforming it into a flexible withdrawable unit for easy maintenance and inspection within switchgear panels.
- Enhanced Safety & Low Maintenance: Vacuum, as an interruption medium, is environmentally friendly (no SF6 gas) and requires minimal maintenance for the interrupter itself, leading to reduced operational costs and downtime.
- Long Mechanical and Electrical Life: Built for durability, offering a high mechanical endurance and a significant number of operations at rated current and rated short-circuit current (see specifications).

Key Technical Specifications
The VS1-24 series offers a range of configurations to meet diverse application requirements. Below are the primary technical parameters:
| No. | Item | Unit | Data |
|---|---|---|---|
| 1 | Rated Voltage | kV | 24 |
| 2 | Rated Short-time Power Freq. Withstand (1min) | kV | 65/79 (Phase-to-Phase, Phase-to-Earth / Across Open Contacts) |
| 3 | Rated Lightning Impulse Withstand (Peak) | kV | 125/145 (Phase-to-Phase, Phase-to-Earth / Across Open Contacts) |
| 4 | Rated Frequency | Hz | 50 |
| 5 | Rated Current | A | 630, 1250, 1600, 2000, 2500, 3150 |
| 6 | Rated Short-Circuit Breaking Current | kA | 20/25, 31.5, 40 |
| 7 | Rated Short-Time Withstand Current | kA | 20/25, 31.5, 40 |
| 8 | Rated Short-Circuit Duration | s | 4 |
| 9 | Rated Peak Withstand Current | kA | 50/63, 80, 100 |
| 10 | Rated Short-Circuit Making Current | kA | 50/63, 80, 100 |
| 11 | Secondary Circuit Power Freq. Withstand (1min) | V | 2000 (Typo, likely should be 2kV or 2000V) |
| 12 | Rated Single/Back-to-Back Capacitor Bank Breaking Current | A | 630/400 (800/400 for 40kA models) |
| 13 | Rated Capacitor Bank Closing Inrush Current | kA | 12.5 (Frequency ≤1000Hz) |
| 14 | Mechanical Endurance | Ops | 20,000 |
| 15 | Electrical Endurance (at Rated Current) | Ops | 20,000 |
| 16 | Rated Short-Circuit Breaking Operations | Ops | 50 (≤30 for 40kA models) |
| 17 | Allowable Cumulative Contact Wear | mm | 3 |
| 18 | Stored Energy Charging Time | s | ≤10 |
| 19 | Contact Opening Distance | mm | 16 ± 1 |
| 20 | Contact Overtravel (Compression) | mm | 3.5 ± 0.5 |
| 21 | Contact Closing Bounce Time | ms | ≤2 (≤3 for 40kA models) |
| 22 | Three-Phase Opening/Closing Asynchronism | ms | ≤2 |
| 23 | Average Opening Speed (Contacts -8mm) | m/s | 1.5 ± 0.2 |
| 24 | Average Closing Speed (8mm – Contacts) | m/s | 0.8 ± 0.2 |
| 25 | Main Circuit Resistance | µΩ | ≤50 (630A), ≤45 (1250A), ≤35 (1600-2000A), ≤25 (>2500A) |
| 26 | Rated Operating Sequence | O – 0.3s – CO – 180s – CO |
Note: Specific values for items 5, 6, 7, 9, 10, 12, 16, 21, and 25 vary based on the selected model configuration. Please consult our detailed datasheets for precise specifications matching your needs.

Typical Applications
The versatility and robust performance of the VS1-24 make it an ideal choice for a wide range of indoor applications, including:
- Medium Voltage Distribution Substations
- Industrial Power Systems (e.g., manufacturing plants, chemical facilities, paper mills)
- Mining Operations
- Commercial Buildings and Infrastructure Projects
- Power Generation Plants (as auxiliary switchgear)
- Any system requiring reliable 24kV circuit protection with frequent switching or high fault current interruption capabilities.
Dimensional Information & Installation
The VS1-24 is designed for straightforward installation and integration. Detailed outline and mounting dimension drawings are available to ensure seamless incorporation into your new or existing switchgear.

Ready to Enhance Your Power System’s Reliability?
The VS1-24 Indoor High Voltage Vacuum Circuit Breaker offers a dependable, low-maintenance, and high-performance solution for your 24kV circuit protection needs. Its adaptability for both fixed and withdrawable installations, coupled with its proven vacuum interruption technology, makes it a smart investment for critical power systems.
Contact our expert team today to discuss your specific requirements, request a detailed quotation, or learn more about how the VS1-24 can benefit your operations.
When to Consider a Blog Post (As You Suggested):
Your suggestions for blog posts are spot on. They serve a different purpose than this core product page:
- Deeper Dives & Education:
- “Applications of 24kV Vacuum Circuit Breakers in Smart Grids”
- “How to Properly Maintain Your 24kV Vacuum Circuit Breaker to Extend Its Lifespan”
- “Technical Deep Dive: The Advantages of Vacuum Interruption at 24kV”
- “Understanding Rated Operating Sequence (O-0.3s-CO-180s-CO) for VCBs”
- Problem Solving & Guidance:
- “Troubleshooting Common Issues with 24kV Vacuum Circuit Breakers”
- “Choosing the Right Rated Current and Breaking Capacity for Your 24kV VCB”
- Comparisons & Industry News:
- “Comparative Analysis: 24kV Vacuum Circuit Breakers vs. SF6 Circuit Breakers – An Environmental and Performance Perspective”
- “Latest Innovations and Trends in 24kV VCB Technology”
- Case Studies & Real-World Examples:
- “Case Study: Successful Implementation of VS1-24 VCBs in [Specific Industry/Project]”
These blog posts would link back to this main VS1-24 product page, driving traffic and providing valuable, specific content for users at different stages of their research or decision-making process.
This article structure provides comprehensive information for a potential customer, focusing on their needs and the product’s benefits, supported by essential technical data. Remember to replace bracketed image suggestions with actual high-quality images.